INDEXED MORSE TAPER Singular
The Singular implant manufactured by Dérig Implantes do Brasil has the indexed Morse Taper internal connection unified for all implant diameters. It has retention grooves in threads, optimizing the bone-implant contact, which increases primary stability. The Singular implant is available at Ø 3.5 mm – Ø 4.3 mm and Ø 5.0 mm diameters. All Dérig implants have the Biotite surface treated by means of double acid attack.
Instructions for Use WHERE TO BUYFeatures
- Tapered implant
- One single Indexed Morse Taper internal connection for all implant diameters
- Retention grooves in threads, optimizing the bone-implant contact, increasing primary stability
- Biotite surface: microporosity obtained through double acid attack, increasing secondary stability
- High versatility:
- Singular 3,5
- Singular 4,3
- Singular 5,0
- Minimizes screw loosening
- Components with indexation
Drilling | Insertion | Max. Torque |
---|---|---|
800-1200 rpm | 30 rpm | 45 Ncm |
Technical Information
NP Implants
Length | “D” | “p” | “b” | “d” | “L” | Code |
---|---|---|---|---|---|---|
8,0 mm | Ø 3,75 mm | Ø 2,75 mm | 0,65 mm | Ø 2,3 mm | 8,5 mm | 02.12.16.101 |
10 mm | 10,5 mm | 02.12.16.102 | ||||
11,5 mm | 12 mm | 02.12.16.103 | ||||
13 mm | 13,5 mm | 02.12.16.104 | ||||
16 mm | 16,5 mm | 02.12.16.105 |
RP Implants
Length | “D” | “p” | “b” | “d” | “L” | Code |
---|---|---|---|---|---|---|
8,0 mm | Ø 4,3 mm | Ø 2,75 mm | 0,70 mm | Ø 2,6 mm | 8,5 mm | 02.12.16.106 |
10 mm | 10,5 mm | 02.12.16.107 | ||||
11,5 mm | 12 mm | 02.12.16.108 | ||||
13 mm | 13,5 mm | 02.12.16.109 | ||||
16 mm | 16,5 mm | 02.12.16.110 |
RP Implants
Length | “D” | “p” | “b” | “d” | “L” | Code |
---|---|---|---|---|---|---|
8,0 mm | Ø 5,0 mm | Ø 2,75 mm | 0,75 mm | Ø 2,9 mm | 8,5 mm | 02.12.16.111 |
10 mm | 10,5 mm | 02.12.16.112 | ||||
11,5 mm | 12 mm | 02.12.16.113 | ||||
13 mm | 13,5 mm | 02.12.16.114 | ||||
16 mm | 16,5 mm | 02.12.16.115 |
Description | Platform | Collar height | Code |
---|---|---|---|
Cover Screw | NP | 02.12.09.001 | |
Healing Abutment | NP | 3 mm | 02.12.02.001 |
NP | 5 mm | 02.12.02.002 | |
NP | 7 mm | 02.12.02.003 |
Biotite Surface
With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.
Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.
Get to Know this technologyDrill protocol
Start Drill | Ø 2,0 | Tapered drill Ø 3,5 |
Tapered drill Ø 4,3 |
Tapered drill Ø 5,0 |
Screw tap | |
---|---|---|---|---|---|---|
Ø 3,5 | ||||||
Ø 4,3 | ||||||
Ø 5,0 |
Required
Optional based on bone density
Implant Driver
- Higher mechanical resistance to insertion
- Improves safety in implant transportation
- Preserves the morse taper prosthetic indexer integrity
Placement of the implant may be started with the capture wrench at contra-angle. Later, insertion should be completed with the manual torque wrench.
Description | Code | |
---|---|---|
CMI NP Short Implant driver | 02.01.11.060 | |
CMI NP Long Implant driver | 02.01.11.062 |