Home > Products > Implants > Indexed Morse Taper

Singular

Implante Singular - Cone Morse Indexado | Dérig

INDEXED MORSE TAPER Singular

The Singular implant manufactured by Dérig Implantes do Brasil has the indexed Morse Taper internal connection unified for all implant diameters. It has retention grooves in threads, optimizing the bone-implant contact, which increases primary stability. The Singular implant is available at Ø 3.5 mm – Ø 4.3 mm and Ø 5.0 mm diameters. All Dérig implants have the Biotite surface treated by means of double acid attack.

Instructions for Use WHERE TO BUY

Features

  • Tapered implant
  • One single Indexed Morse Taper internal connection for all implant diameters
  • Retention grooves in threads, optimizing the bone-implant contact, increasing primary stability
  • Biotite surface: microporosity obtained through double acid attack, increasing secondary stability
  • High versatility:
    • Singular 3,5
    • Singular 4,3
    • Singular 5,0
    • Minimizes screw loosening
    • Components with indexation
Drilling Insertion Max. Torque
800-1200 rpm 30 rpm 45 Ncm

Technical Information

Guias para as medidas do implante Cone Morse Indexado Singular

NP Implants

Length “D” “p” “b” “d” “L” Code
8,0 mm Ø 3,75 mm Ø 2,75 mm 0,65 mm Ø 2,3 mm 8,5 mm 02.12.16.101
10 mm 10,5 mm 02.12.16.102
11,5 mm 12 mm 02.12.16.103
13 mm 13,5 mm 02.12.16.104
16 mm 16,5 mm 02.12.16.105

RP Implants

Length “D” “p” “b” “d” “L” Code
8,0 mm Ø 4,3 mm Ø 2,75 mm 0,70 mm Ø 2,6 mm 8,5 mm 02.12.16.106
10 mm 10,5 mm 02.12.16.107
11,5 mm 12 mm 02.12.16.108
13 mm 13,5 mm 02.12.16.109
16 mm 16,5 mm 02.12.16.110

RP Implants

Length “D” “p” “b” “d” “L” Code
8,0 mm Ø 5,0 mm Ø 2,75 mm 0,75 mm Ø 2,9 mm 8,5 mm 02.12.16.111
10 mm 10,5 mm 02.12.16.112
11,5 mm 12 mm 02.12.16.113
13 mm 13,5 mm 02.12.16.114
16 mm 16,5 mm 02.12.16.115
Description Platform Collar height Code
Cover Screw NP 02.12.09.001
Healing Abutment NP 3 mm 02.12.02.001
NP 5 mm 02.12.02.002
NP 7 mm 02.12.02.003
microscopia força atômica

Biotite Surface

With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.

Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.

Get to Know this technology

Drill protocol

Start Drill Ø 2,0 Tapered drill
Ø 3,5
Tapered drill
Ø 4,3
Tapered drill
Ø 5,0
Screw tap
Ø 3,5
Ø 4,3
Ø 5,0

Required

Optional based on bone density

Implant Driver

  • Higher mechanical resistance to insertion
  • Improves safety in implant transportation
  • Preserves the morse taper prosthetic indexer integrity

Placement of the implant may be started with the capture wrench at contra-angle. Later, insertion should be completed with the manual torque wrench.

Description Code
CMI NP Short Implant driver 02.01.11.060
CMI NP Long Implant driver 02.01.11.062
Chave