External Hexagon (Short Implant) | HEXKort HEX
Kort is a short implant manufactured by Dérig Implantes do Brasil. With its parallel macrogeometry slightly tapered in its apical portion, it has an external hexagonal interface and presents a line with reduced platform (swifting). Kort is available at Ø 4 mm and Ø 5 mm diameters. All Dérig implants have the Biotite surface treated by means of double acid attack. A cover screw accompanies this implant.
Instructions of Use WHERE TO BUYFeatures
- Parallel Implants 4.0 and 5.0 diameters
- Parallel implant slightly tapered at the apical portion
- External Hexagonal interface
- Short parallel implant 5.5 mm and 7 mm length
- Internal torque with capture and insertion grip system
- Double threads to speed up insertion and minimize traumas
- Cutting chambers at the apical region
- Retention grooves in threads
- Biotite surface: Microporosity obtained through double acid etched, increasing secondary stability
- Easy capture and insertion
- Implant driver for torque wrench final torque
- Color coded wrench for make prosthetic platform identification easy: magenta for NP and yellow for RP platforms
Technical Information
Implants Ø 4,0 mm
Length | “h” | “p” | “a” | “b” | “D” | “d” | “L” | Code | Components |
---|---|---|---|---|---|---|---|---|---|
5,5 mm | 0,7 mm | Ø 3,5 mm | 2,4 mm | 1,0 mm | Ø 4,0 mm | Ø 3,70 mm | 5,5 mm | 02.03.16.049 | HEX NP |
7,0 mm | 7 mm | 02.03.16.050 |
Implants Ø 5,0 mm
Length | “h” | “p” | “a” | “b” | “D” | “d” | “L” | Code | Components |
---|---|---|---|---|---|---|---|---|---|
5,5 mm | 0,7 mm | Ø 4,1 mm | 2,7 mm | 1,2 mm | Ø 5,0 mm | Ø 4,70 mm | 5,5 mm | 02.03.16.051 | HEX RP-UP |
7,0 mm | 7 mm | 02.03.16.052 |
Biotite Surface
With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.
Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.
Get to Know this technologyDrilling protocol*
Start Drill | Ø 2,0 | Ø 2,8 | Ø 3,2 | Ø 3,6 | Ø 4,2 | Ø 4x5,5 | Ø 4x7 | Ø 5x5,5 | Ø 5x7 | |
---|---|---|---|---|---|---|---|---|---|---|
Ø 4x5,5 | ||||||||||
Ø 4x7 | ||||||||||
Ø 5x5,5 | ||||||||||
Ø 5x7 |
Required
* We recommend the use of the Kort Drill Kit
Implant Driver
- Higher mechanical resistance to insertion
- Improves safety in implant transportation
- Preserves the morse taper prosthetic indexer integrity
Placement of the implant may be started with the capture wrench at contra-angle.
Later, insertion should be completed with the manual torque wrench.
Description | Code |
---|---|
CA HEX NP Medium Implant Driver | 02.01.11.076 |
CA HEX RP-UP Short Implant Driver | 02.01.11.096 |
CA HEX RP-UP Medium Implant Driver | 02.01.11.077 |
TW HEX NP Short Implant Driver | 02.01.11.050 |
TW HEX NP Medium Implant Driver | 02.01.11.051 |
TW HEX RP-UP Short Implant Driver | 02.01.11.053 |
TW HEX RP-UP Medium Implant Driver | 02.01.11.054 |