Home > Products > Implants > HEX > Kort HEX

Kort HEX

Implante Kort - Hexágono Externo | Dérig

External Hexagon (Short Implant) | HEXKort HEX

Kort is a short implant manufactured by Dérig Implantes do Brasil. With its parallel macrogeometry slightly tapered in its apical portion, it has an external hexagonal interface and presents a line with reduced platform (swifting). Kort is available at Ø 4 mm and Ø 5 mm diameters. All Dérig implants have the Biotite surface treated by means of double acid attack. A cover screw accompanies this implant.

Instructions of Use WHERE TO BUY

Features

  • Parallel Implants 4.0 and 5.0 diameters
  • Parallel implant slightly tapered at the apical portion
  • External Hexagonal interface
  • Short parallel implant 5.5 mm and 7 mm length
  • Internal torque with capture and insertion grip system
  • Double threads to speed up insertion and minimize traumas
  • Cutting chambers at the apical region
  • Retention grooves in threads
  • Biotite surface: Microporosity obtained through double acid etched, increasing secondary stability
  • Easy capture and insertion
  • Implant driver for torque wrench final torque
  • Color coded wrench for make prosthetic platform identification easy: magenta for NP and yellow for RP platforms

Technical Information

Guias para as medidas do implante Hexágono Externo Kort

Implants Ø 4,0 mm

Length “h” “p” “a” “b” “D” “d” “L” Code Components
5,5 mm 0,7 mm Ø 3,5 mm 2,4 mm 1,0 mm Ø 4,0 mm Ø 3,70 mm 5,5 mm 02.03.16.049 HEX NP
7,0 mm 7 mm 02.03.16.050

Implants Ø 5,0 mm

Length “h” “p” “a” “b” “D” “d” “L” Code Components
5,5 mm 0,7 mm Ø 4,1 mm 2,7 mm 1,2 mm Ø 5,0 mm Ø 4,70 mm 5,5 mm 02.03.16.051 HEX RP-UP
7,0 mm 7 mm 02.03.16.052
microscopia força atômica

Biotite Surface

With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.

Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.

Get to Know this technology

Drilling protocol*

Start Drill Ø 2,0 Ø 2,8 Ø 3,2 Ø 3,6 Ø 4,2 Ø 4x5,5 Ø 4x7 Ø 5x5,5 Ø 5x7
Ø 4x5,5
Ø 4x7
Ø 5x5,5
Ø 5x7

Required

* We recommend the use of the Kort Drill Kit

Implant Driver

  • Higher mechanical resistance to insertion
  • Improves safety in implant transportation
  • Preserves the morse taper prosthetic indexer integrity

Placement of the implant may be started with the capture wrench at contra-angle.
Later, insertion should be completed with the manual torque wrench.

Description Code
CA HEX NP Medium Implant Driver 02.01.11.076
CA HEX RP-UP Short Implant Driver 02.01.11.096
CA HEX RP-UP Medium Implant Driver 02.01.11.077
TW HEX NP Short Implant Driver 02.01.11.050
TW HEX NP Medium Implant Driver 02.01.11.051
TW HEX RP-UP Short Implant Driver 02.01.11.053
TW HEX RP-UP Medium Implant Driver 02.01.11.054
Chave