Home > Products > Implants > HI > Exakort HI

Exakort HI

Implante Kort - Hexágono Externo | Dérig

Internal Hexagon | HIExakort HI

The Exakort HI presents precise cutting and self tapping characteristics that improves bone condensation and preservation. It`s designed to offer high initial stability for all loading protocols with a minor inserction trauma. The macro design enables clinicians to ajust the implant position The double acid treated surface, Biotite, improves secondary stability and promotes long term success. The internal hex connection offers a tight seal and hight restoration stability. Implant diameters are of 3.3mm, 3.8mm, 4.2mm.

Instructions of Use WHERE TO BUY

Features

  • A single Internal Hexagon Interface for all implant diameters;
  • Retention grooves in threads: increases bone implant contact area and primary stability;
  • Biotite surface: Microporosity obtained through double acid etched, increasing secondary stability;
  • Implant diameters:
    • Exakort HI 3,3
    • Exakort HI 3,8
    • Exakort HI 4,2

Technical Information

Guias para as medidas do implante Hexágono Externo Kort

Implants Ø 3,3 mm

Length “D” “P1” “P” “b” “d” “L” Code Components
8 mm Ø 3,3 mm Ø 3,5 mm Ø 3,4 mm 2,3 mm Ø 2,5 mm 8 mm 02.15.16.001 HI
10 mm 10 mm 02.15.16.002
11,5 mm 11,5 mm 02.15.16.003
13 mm 13 mm 02.15.16.004
15 mm 15 mm 02.15.16.005

Implants Ø 3,8 mm

Length “D” “P1” “P” “b” “d” “L” Code Components
8 mm Ø 3,8 mm Ø 3,8 mm Ø 3,7 mm 2,3 mm Ø 3 mm 8 mm 02.15.16.006 HI
10 mm 10 mm 02.15.16.007
11,5 mm 11,5 mm 02.15.16.008
13 mm 13 mm 02.15.16.009
15 mm 15 mm 02.15.16.010

Implants Ø 4,2 mm

Length “D” “P1” “P” “b” “d” “L” Code Components
8 mm Ø 4,2 mm Ø 4,2 mm Ø 3,7 mm 2,3 mm Ø 3,4 mm 8 mm 02.15.16.011 HI
10 mm 10 mm 02.15.16.012
11,5 mm 11,5 mm 02.15.16.013
13 mm 13 mm 02.15.16.014
15 mm 15 mm 02.15.16.015
microscopia força atômica

Biotite Surface

With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.

Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.

Get to Know this technology

Drilling protocol

Start Drill Ø 2,3 Ø 2,8 Ø 3,0 Ø 3,15 Ø 3,5
Ø 3,3
Ø 3,8
Ø 4,2

Required

Optional based on bone density

Implant Driver

  • Internal torque with grip system for capture and insertion;
  • Increased mechanical resistance to insertion;
  • Enhanced safety in the implant transportation;
  • Increased integrity maintenance of the internal hexagon;

The implant insertion can be initiated with the capture key at counter-angle.
The insertion must be finished with manual torquemeter afterwards.

Description Code
HI Short Implant Driver 02.01.11.063
HI Long Implant Driver 02.01.11.064
Chave