Home > Products > Implants > Indexed Morse Taper

Dynamic

Implante Kort - Hexágono Externo | Dérig

INDEXED MORSE TAPERDynamic

The Dynamic implant manufactured by Dérig Implantes do Brasil has the Indexed Morse Taper internal interface unified for all implant diameters. With its tapered central core, the implant has double progressive threads, which provide high primary stability. The Dynamic implant is available at Ø 3.5 mm – Ø 4.3 mm and Ø 5.0 mm diameters. All Dérig implants have the Biotite surface treated by means of double acid attack.

Instructions of Use WHERE TO BUY

Features

  • Parallel implant
  • One single Indexed Morse Taper internal interface for all implant diameters
  • Implant with tapered central core
  • Double progressive threads
  • High primary stability
  • Biotite surface: microporosity obtained through double acid attack, increasing secondary stability
  • High versatility:
    • Dynamic 3,5
    • Dynamic 4,3
    • Dynamic 5,0
    • Minimizes screw loosening
    • Components with indexation
Drilling Insertion Max. Torque
800-1200 rpm 30 rpm 45 Ncm

Technical Information

Guias para as medidas do implanteCone Morse Indexado Dynamic

NP Implants

Length “D” “p” “b” “d” “L” Code
8,5 mm Ø 3,6 mm Ø 2,75 mm 2,4 mm Ø 2,8 mm 8 mm 02.12.16.001
10 mm 9,5 mm 02.12.16.002
11,5 mm 11 mm 02.12.16.003
13 mm 12,5 mm 02.12.16.004
15 mm 14,5 mm 02.12.16.005

RP Implants

Length “D” “p” “b” “d” “L” Code
8,5 mm Ø 4,3 mm Ø 2,75 mm 2,4 mm Ø 3,2 mm 8 mm 02.12.16.006
10 mm 9,5 mm 02.12.16.007
11,5 mm 11 mm 02.12.16.008
13 mm 12,5 mm 02.12.16.009
15 mm 14,5 mm 02.12.16.010

RP Implants

Length “D” “p” “b” “d” “L” Code
8,5 mm Ø 5,0 mm Ø 2,75 mm 2,4 mm Ø 3,6 mm 8 mm 02.12.16.011
10 mm 9,5 mm 02.12.16.012
11,5 mm 11 mm 02.12.16.013
13 mm 12,5 mm 02.12.16.014
15 mm 14,5 mm 02.12.16.015
Description Platform Collar height Code
Cover Screw NP 02.12.09.001
Healing Abutment NP 3 mm 02.12.02.001
NP 5 mm 02.12.02.002
NP 7 mm 02.12.02.003
microscopia força atômica

Biotite Surface

With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.

Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.

Get to Know this technology

Drill protocol

Start Drill Ø 2,0 Ø 2,8 Ø 3,0 Ø 3,15 Ø 3,5 Ø 4,3 Countersink UN
Ø 3,5 mm
Ø 4,3 mm
Ø 5,0 mm

Required

Optional based on bone density

Implant Driver

  • Higher mechanical resistance to insertion
  • Improves safety in implant transportation
  • Preserves the Cone Morse prosthetic indexer integrity

The implant placement may be started with the capture wrench at contra-angle. Later on, insertion should be completed with the manual torque wrench.

Description Code
CMI NP Short Implant driver 02.01.11.060
CMI NP Long Implant driver 02.01.11.062
Chave