Home > Products > Implants > TRI > Bioneck TRI

Bioneck TRI

Implante Bioneck - Triplo Canal Interno | Dérig

Internal Triplo Channel | TRI Bioneck TRI

Bioneck implant manufactured by Dérig Implantes do Brasil has the internal triple channel interface. With high compression power, the implant has retention grooves in threads, optimizing the bone-implant contact, which increases primary stability. Bioneck implant is available at Ø 3.5 mm – Ø 4.3 mm and Ø 5.0 mm diameters. All Dérig implants have the Biotite surface treated by means of double acid attack. A cover screw accompanies this implant.

Instructions of Use WHERE TO BUY

Features

  • Tapered implant
  • Internal triple channel interface
  • Internal torque with capture and insertion system
  • Cervical microchannels
  • Macrogeometry with high primary stability
  • Retention grooves in threads: increases bone implant contact area and primary stability
  • Biotite surface: microporosity obtained through double acid etched, increasing secondary stability
  • Easy capture and insertion
  • Color markings indicate the correct placement
  • Depth measuring device
  • Mechanical Grip System

Technical Information

Guias para as medidas do implante Triplo Canal Interno Bioneck

Implants Ø 3,5 mm

Length “D” “P” “b” “d” “L” Code Components
8,0 mm Ø 3,75 mm Ø 3,5 mm 0,65 mm Ø 2,3 mm 8,5 mm 02.04.16.001 TRI NP
10 mm 10,5 mm 02.04.16.002
11,5 mm 12 mm 02.04.16.053
13 mm 13,5 mm 02.04.16.003
16 mm 16,5 mm 02.04.16.004

Implants Ø 4,3 mm

Length “D” “p” “b” “d” “L” Code Components
8,0 mm Ø 4,3 mm Ø 4,3 mm 0,70 mm Ø 2,7 mm 8,5 mm 02.04.16.005 TRI RP-UP
10 mm 10,5 mm 02.04.16.006
11,5 mm 12 mm 02.04.16.054
13 mm 13,5 mm 02.04.16.007
16 mm 16,5 mm 02.04.16.008

Implants Ø 5,0 mm

Length “D” “p” “b” “d” “L” Code Components
8,0 mm Ø 5,0 mm Ø 4,3 mm 0,75 mm Ø 2,9 mm 8,5 mm 02.04.16.025 TRI RP-UP
10 mm 10,5 mm 02.04.16.026
11,5 mm 12 mm 02.04.16.055
13 mm 13,5 mm 02.04.16.027
16 mm 16,5 mm 02.04.16.028
Guias para as medidas do implante Triplo Canal Interno Bioneck

Implants Ø 4,3 mm

Length “D” “P” “b” “d” “L” Code Components
8,0 mm Ø 4,3 mm Ø 3,5 mm 0,70 mm Ø 2,7 mm 8,5 mm 02.04.16.059 TRI NP
10 mm 10,5 mm 02.04.16.060
11,5 mm 12 mm 02.04.16.061
13 mm 13,5 mm 02.04.16.062
16 mm 16,5 mm 02.04.16.063

Components have a color code to identify their prosthetic interface

microscopia força atômica

Biotite Surface

With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.

Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.

Get to Know this technology

Drilling protocol

Start Drill Ø 2,0 Tapered Drill
Ø 3,5
Tapered Drill
Ø 4,3
Tapered Drill
Ø 5,0
Screw Tap
Ø 3,5
Ø 4,3
Ø 5,0

Required

Optional based on bone density

Implant Driver

  • Higher mechanical resistance to insertion
  • Improves safety in implant transportation
  • Preserves internal triple channel

Placement of the implant may be started with the capture wrench at contra-angle.
Later, insertion should be completed with the manual torque wrench.

Description Code
TRI NP Short Implant Driver 02.01.11.048
TRI NP Long Implant Driver 02.01.11.058
TRI RP- UP Short Implant Driver 02.01.11.049
TRI RP- UP Long Implant Driver 02.01.11.059
Chave