Home > Products > Implants > CMH > Bioneck CMH

Bioneck CMH

Implante Bioneck - Triplo Canal Interno | Dérig

Hexagonal Morse Tapered | CMH Bioneck CMH

The Bioneck CMH implant has a macro-design that mimics the natural dental root form. The implant has a precise cutting and self tapping. It`s designed to offer high initial stability for all loading protocols. The double acid treated surface, Biotite, improves secondary stability and promotes long term success. The CMH morse tapered with an internal hex connection offers a tight seal and hight restoration stability. The implant coronal design and it`s plataform shifting are produced to optimize bone and soft tissue volume. The packtage includes the implant and its cover screw. Implant diameters are of 3.5mm and 4.3mm.

Instructions of Use WHERE TO BUY

Features

  • A single Indexed Morse Tapered internal Interface for all implant diameters
  • Retention grooves on threads to optimize the contact area between the implant and the bone, in order to increase primary stability
  • Biotite surface: Microporosity obtained through double acid etched, increasing secondary stability
  • Implant diameters:
    • Bioneck CMH 3,5
    • Bioneck CMH 4,3

Technical Information

Guias para as medidas do implante Triplo Canal Interno Bioneck

Implants Ø 3,5 mm

Length “D” “P1” “P” “b” “d” “L” Code Componentes
8 mm Ø 3,75 mm Ø 3,5 mm Ø 3 mm 0,65 mm Ø 2,3 mm 8,5 mm 02.23.16.221 CMH NP
10 mm 10,5 mm 02.23.16.222
11,5 mm 12 mm 02.23.16.223
13 mm 13,5 mm 02.23.16.224
16 mm 16,5 mm 02.23.16.225

Implants Ø 4,3 mm

Length “D” “P1” “P” “b” “d” “L” Code Componentes
8,0 mm Ø 4,3 mm Ø 3,9 mm Ø 3 mm 0,7 mm Ø 2,7 mm 8,5 mm 02.23.16.251 CMH NP
10 mm 10,5 mm 02.23.16.252
11,5 mm 12 mm 02.23.16.253
13 mm 13,5 mm 02.23.16.254
16 mm 16,5 mm 02.23.16.255
microscopia força atômica

Biotite Surface

With large-scale investments in research and development, Dérig achieved high quality in implant surface treatment, with the purpose of providing more safety and clinical stability.

Increased hydrophilia enables the concept of secondary osseointegration and higher postoperative healing speed.

Get to Know this technology

Drilling Protocol

Starter Drill Ø 2,0 Tapered Drill
Ø 3,5
Tapered Drill
Ø 4,3
Tapered Drill
Ø 5,0
Screw Tap
Ø 3,5
Ø 4,3

Required

Optional based on bone density

Implant Driver

  • Internal torque with grip system for capture and insertion
  • Increased mechanical resistance to insertion
  • Increased integrity maintenance of the morse tapered connection
  • A single insertion driver for torque wrench and contra-angle

The implant insertion can be started with the capture driver at contra-angle.
The insertion must be finished with manual torque wrench afterwards.

Description Code
CMH NP Short Implant Driver 02.01.11.233
CMH NP Long Implant Driver 02.01.11.234
Chave